HMI
    ROP operate Panel
    RT Series Touch Screen
    MP series
    TH series touch screen
  Programmable controllers
    RH series
       RH1(economical)
       RH2(basic type)
       RH3(standard)
       RH5(enhanced)
       Motion control RHM series
       Expansion modules
       Expansion BD board
    Special Models
       T-BOX
       G-BOX
    MA series modules
  Integrated PLC+HMI
    RX series
    RMX series
    RX series expansion BD board
  Inverter
    F5 (Open loop vector control)
    V5 (VVVF control)
  Step Drive
    2-phase driver
    3-phase driver
 
   
Address: 4 th Floor, Building 7, Originality Industry Park , LiYuan Development Zone, Wuxi city, JiangSu Provinc,
Tel: +86-21-56322066
Fax: +86-21-56322611
     
  Product Line-up Home>Products>Product Line-up
     
 

RH3(standard)
 
8 DI/6 DO, AC220 power supply
Support power-off retentive
Support basic logic control and data operation
Support high speed count, pulse output, external interruption, C language function block, free switch for I/O points, free protocol communication and MODBUS communication.
Can not support expansion module and BD board.
 

General Specifications


Item

Specification

Insulation Voltage

Above DC 500V 2MΩ

Noise Resistance

1000V 1uS pulse for 1 minute

Environment Temperature

0℃~60℃

Ambient Humidity

5%~95%

COM 1

RS-232, be connected to host machine or HMI for programming or debugging

COM 2

RS-485 or RS-232,network or connect to intelligent instrument, inverter, etc.

Installation

M3 screw fixed or DIN46277 (35mm width) guide rail installation

Grounding

The third type grounding (Never perform common grounding with strong power system)

Functional Specifications

Item
Specification
Program operation Mode
Circulation scanning mode, timing scanning mode
Program Mode
Instructions and ladder chart
Dispose Speed
0.5us
Power Failure Holding
FlashROM
User Program’s Capacity
2500 steps
I/O Points
8 input points,6 output points
Output Format
Relay
Power Supply
AC220V
Interior Coil’s Points (M)
8512 points
 
Timer(T)
Points
620 points
Specification
100mS timer:set time 0.1~3276.7 seconds
10mS timer:set time 0.01~327.67 seconds
1mS timer:set time 0.001~32.767 seconds
 
Counter(C)
Points
635 Points
Specification
16 bits counter::Set value K0~32767
32 bits counter:Set value K0~2147483647
Data Register(D)
8512 characters
FlashROM Register(FD)
2048 characters
High-speed Count Format
High speed counter, pulse output, exterior interruption
Timing Scanning Interval Setting
1~99mS
Password Protection
6 characters ASCII
Self-diagnose Function
Power on self-diagnose, monitor timer, grammar check













 

 

 

 

 

 

 


Dimensions:

 
 