HMI
    ROP operate Panel
    RT Series Touch Screen
    MP series
    TH series touch screen
  Programmable controllers
    RH series
       RH1(economical)
       RH2(basic type)
       RH3(standard)
       RH5(enhanced)
       Motion control RHM series
       Expansion modules
       Expansion BD board
    Special Models
       T-BOX
       G-BOX
    MA series modules
  Integrated PLC+HMI
    RX series
    RMX series
    RX series expansion BD board
  Inverter
    F5 (Open loop vector control)
    V5 (VVVF control)
  Step Drive
    2-phase driver
    3-phase driver
 
   
Address: 4 th Floor, Building 7, Originality Industry Park , LiYuan Development Zone, Wuxi city, JiangSu Provinc,
Tel: +86-21-56322066
Fax: +86-21-56322611
     
  Product Line-up Home>Products>Product Line-up
     
 

Motion control RHM series
  Special PLC for motion control
Invoke G code directly in RHP Pro software
Larger capacity and higher processing speed
Can be connected with expansion module and BD board, support MODBUS
 

Functional Specifications

Item
Specification
Program operation Mode
Circulation scanning mode, timing scanning mode
Program Mode
Instructions and ladder chart
Dispose Speed
0.5us
Power Failure Holding
FlashROM
User Program’s Capacity
8000 steps (24K Steps in protective download)
I/O Points
18 input points,14 output points
Interior Coil’s Points (M)
8000 points
Step
1024 points
 
Timer(T)
Points
620 points
Specification
100mS timer:set time 0.1~3276.7 seconds
10mS timer:set time 0.01~327.67 seconds
1mS timer:set time 0.001~32.767 seconds
with interruption accuracy timer
 
Counter(C)
Points
635 Points
Specification
16 bits counter::Set value K0~32767
32 bits counter:Set value K0~2147483647
Data Register(D)
5000 characters
FlashROM Register(FD)
64 characters
Expansion Internal Register (ED)
36864 characters
High-speed Count Format
High speed counter, pulse output, exterior interruption
Timing Scanning Interval Setting
1~99mS
Password Protection
6 characters ASCII
Self-diagnose Function
Power on self-diagnose, monitor timer, grammar check
Item
Specification
Program operation Mode
Circulation scanning mode, timing scanning mode
Program Mode
Instructions and ladder chart
Dispose Speed
0.5us
Power Failure Holding
FlashROM
User Program’s Capacity
8000 steps
I/O Points
18 input points,14 output points
Output Format
Relay
Power Supply
AC220V
Interior Coil’s Points (M)
8512 points
 
Timer(T)
Points
620 points
Specification
100mS timer:set time 0.1~3276.7 seconds
10mS timer:set time 0.01~327.67 seconds
1mS timer:set time 0.001~32.767 seconds
 
Counter(C)
Points
635 Points
Specification
16 bits counter::Set value K0~32767
32 bits counter:Set value K0~2147483647
Data Register(D)
8512 characters
FlashROM Register(FD)
2048 characters
High-speed Count Format
High speed counter, pulse output, exterior interruption
Timing Scanning Interval Setting
1~99mS
Password Protection
6 characters ASCII
Self-diagnose Function
Power on self-diagnose, monitor timer, grammar check

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 


 

 
 
Copyright(c)2007 Rockhood Automation Ltd All rights reserved